Kolbe Ultra 2020

Double Hungs | Elevation Charts

Sterling & Traditional Double Hungs | 30 º Bay Windows

16" flankers 30° Bay Windows 16" ankers

20" ankers

20" flankers

UNIT PROJECTION: 13 3/8"

UNIT PROJECTION: 15 3/8"

8'-7 9/16" 8'-5 15/16"

8'-8 5/8" 8'-7"

9'-3 9/16" 9'-1 15/16"

8'-0 5/8" 7'-11"

U.D.

R.O.

2'-0" | 4'-4" | 2'-0" 20" | 48 1/2" | 20"

1'-8" | 5'-0" | 1'-8" 16" | 56 1/2" | 16"

2'-0" | 5'-0" | 2'-0" 20" | 56 1/2" | 20"

1'-8" | 4'-4" | 1'-8" 16" | 48 1/2" | 16"

S.O.

G.S.*

30-16224442

30-16225042

30-20224442

30-20225042

30-20244446

30-16244446

30-16245046

30-20245046

30-20285052

Sterling & Traditional Double Hungs | 45 º Bay Windows

45° Bay Win ows 16" ankers

20" ankers

16" flankers

20" flankers

UNIT PROJECTION: 18 7/8"

UNIT PROJECTION: 21 11/16"

7'-8 1/4" 7'-4 7/8"

8'-1 7/8" 7'-10 1/2"

8'-4 1/4" 8'-0 7/8"

8'-9 7/8" 8'-6 1/2"

U.D.

R.O.

1'-8" | 4'-4" | 1'-8" 16" | 48 1/2" | 16"

2'-0" | 4'-4" | 2'-0" 20" | 48 1/2" | 20"

1'-8" | 5'-0" | 1'-8" 16" | 56 1/2" | 16"

2'-0" | 5'-0" | 2'-0" 20" | 56 1/2" | 20"

S.O.

G.S.*

45-16225042

45-20225042

45-16224442

45-20224442

45-20245046

45-16244446

45-16245046

45-20244446

45-20285052

* The first number of the glass size height is the height (per sash) for each flanker sash. The second number is the glass height for the center picture unit. U.D. = Unit Dimension • R.O. = Rough Opening • S.O. = Sash Opening • G.S. = Glass Size

NOTE: All measurements are nominal. Elevation charts are not to scale. Divided lites are optional. Center picture units are only available with a 1-3/4" sash. Flanker sash must be specified as either Traditional or Sterling sash when ordering. If the cable support system and/or insulated platforms and support brackets are not being used, other means of proper support must be used. Add 1-13/16" to the R.O. height if an insulated platform is being used. R.O.’s for bay units without head and seat boards, typically used for walk-out applications, are different. Some installation procedures will require a larger rough opening than noted (i.e. installations utilizing our installation clips), therefore, you may need to increase the rough opening size accordingly. Rough opening gaps may be increased up to a maximum of 1/2" on all sides and still be within good practice guidelines. For rough opening recommendations, see pg. 216. The side jambs of double hung units extend above the head jamb; additional space for the rough opening height may be necessary. Additional and the most current drawings are available at www.kolbewindows.com .

Kolbe Windows & Doors 86